This research formulates an urban heat island mitigation framework for the semi-arid metropolitan region of Ahmedabad, Gujarat. Using a 1 km × 1 km spatial discretization, the project incorporates a simplified 2D thermal PDE regularizer into neural networks to model surface skin cooling sensitivity (ΔLST) and near-surface air cooling estimates (ΔT_air).
- Spatial Generalization: Evaluating on contiguous 8 km blocks prevents spatial adjacency leakage and provides a rigorous out-of-sample evaluation, revealing a substantial generalization gap for tree ensembles under spatial block holdouts (test R² drops to 0.034 despite high training fit).
- PINN Regularization: The physics loss (λ_pde = 0.1) acts as a numerical regularizer, reducing the formulated 2D thermal PDE residual MSE by 22.2% (from 0.962 down to 0.748) while maintaining 0.32 °C MAE.
- Canopy Decoupling: Pedestrian 2m air cooling is attenuated relative to radiometric rooftop skin cooling (ΔT_air ≈ 0.32 × ΔLST).
- Spatial Prioritization: Multi-Criteria UHVI balances thermal hazard (40%), structural footprint (40%), and vegetative deficit (20%) using empirical rank percentiles.
E250_N2547 holds #1 vulnerability rank (-0.72 °C cooling); domain-wide peak cooling occurs in cell E251_N2548 (-0.88 °C) due to maximum building density (3.30%).
| Rank | Grid ID | Priority Tier | Baseline LST | Building Density | NDVI | UHVI Index | Projected ΔLST | Est. ΔT_air | Targeted Policy Action | Action |
|---|
Modify intervention intensities to simulate counterfactual microclimate responses across all 1,661 grid cells. Calculations use the trained PINN response surface coupled with thermodynamic saturation caps (6.5 °C).
| Model Class | Architecture / Spec | Train R² | Train RMSE | Test R² | Test RMSE | Test MAE | PDE Residual MSE | Primary Scientific Role |
|---|
Thermal Advection-Diffusion PDE Regularizer (Simplified Diffusion-Reaction Formulation):
The PINN optimizes a composite loss combining empirical data fidelity with a simplified thermal PDE regularization residual:
The steady-state 2D diffusion-reaction thermal balance operator penalizes non-physical spatial gradient discontinuities:
Why the PINN has lower R² (0.014 vs 0.056 for Ridge): The physics loss acts strictly as a numerical regularizer. It penalizes non-physical spatial gradient spikes, trading off empirical training-set curve-fitting flexibility to reduce the formulated thermal PDE residual MSE from 0.962 down to 0.748 (22.2% reduction).
Note: A 22.2% reduction in the implemented PDE residual reflects numerical regularization under the formulated 2D steady-state heat equation; it does not establish thermodynamic conservation, prove a physical heat-transfer model, or demonstrate real-world cooling efficacy without empirical microclimate ground truth.
Residual Spatial Autocorrelation (Moran's I):
A residual Moran's I = -0.006 (p = 0.44) fails to reject the null hypothesis of spatial randomness under inverse-distance weighting at this scale. While this demonstrates that the contiguous 8 km spatial block holdout successfully avoided naive spatial autocorrelation leakage, it does not constitute proof of absolute spatial independence across all spatial processes or scales.
Total target variation across the 780 spatial holdout cells is narrow (standard deviation σ = 0.407 °C, Var(LST) = 0.166 °C²). In the offline test generator (tests/synthetic_data.py), an independent Gaussian perturbation with nominal σ = 0.35 °C was added to cell temperatures. Combined with the low prototype building coverage (mean 0.08%) and the strict 8 km spatial block split evaluating models on unseen geographic regimes, this high noise-to-signal ratio limits explainable out-of-sample variance across all model architectures (test R² = 0.01 – 0.06), while absolute errors remain small (RMSE ≈ 0.40 °C, MAE ≈ 0.32 °C).
| Variable / Layer | Source Path on Disk | Generation Method | Authentication / Provenance Status |
|---|---|---|---|
| Building Footprints | 395_buildings.csv (sampled Open Buildings proxy) (1.15 MB, 6,027 rows) |
Offline generator write_buildings_csv() (IDs: SYN0000000) |
Synthetic Prototype (4,777 retained) |
| Municipal Boundary | data/raw/boundary/ahmedabad_municipal_boundary.geojson |
Synthetic ellipse generated by write_boundary() (~462 km²) |
Synthetic Geometric Proxy |
| LST, NDVI, NDBI | data/processed/grid_rasters/grid_landsat_*.tif |
Offline raster generator write_grid_tifs() |
Calibrated Synthetic Proxy |
| PINN Neural Weights | data/processed/models/pinn_model.keras |
Trained via TensorFlow Adam optimizer on 2,542 train samples | Trained Model Artifact |
1. Urban Heat Vulnerability Index (UHVI):
UHVI_i = 0.40·RankPct(LST_i) + 0.40·RankPct(ρ_bld,i) + 0.20·RankPct(1 - NDVI_i)
Empirical rank percentiles (empirical CDF ranks scaled to [0, 1]) are computed across all cells to prevent extreme right-skewed building density outliers from distorting vulnerability prioritization.
2. Non-Linear Cooling Saturation:
ΔLST_comb = 6.5 · [1 - exp(-ΣΔLST_i / (6.5 · 0.85))]
3. Air Temperature Coupling:
ΔT_air ≈ 0.32 · ΔLST (Canopy boundary layer)
- Earth Engine Authentication: Live USGS Landsat rasters require interactive browser OAuth (
earthengine authenticate). In offline mode, the pipeline operates on the calibrated synthetic proxy raster. - Building Sample Extent:
395_buildings.csv (sampled Open Buildings proxy)contains 4,777 buildings inside the study area, resulting in 0.08% mean density. Real city-scale applications require uncompressed municipal building datasets. - Physics Regularization vs. Ground Truth: The 22.2% reduction in the implemented PDE residual indicates compliance with the formulated 2D heat energy operator; it does not substitute for empirical satellite ground-truth validation.
- Synthetic Counterfactuals: Modeled cooling values represent parameter sensitivity projections under the prototype data-generating process, not empirically measured Ahmedabad microclimate cooling.
- Microscale CFD: The 1 km grid resolution averages building canyon geometry. Localized street-level turbulence requires microscale modeling (ENVI-met).
Download verified data tables and reports generated by the analysis pipeline. All exports reflect actual generated numbers with zero manual tampering.
Priority Hotspots CSV
Top 50 critical heat hotspots ranked by UHVI index with policy recommendations.
Full Scenario Results CSV
Complete 1,661 grid cells with counterfactual skin cooling (ΔLST) and ambient air cooling (ΔT_air) across all four mitigation strategies.
Model Benchmarks CSV
Quantitative metrics comparing Mean Baseline, Ridge, RF, MLP, and PINN.